5.4 Recommendations
Recommended
system accuracies and resolutions for meteorological data acquisition systems
are given in Table 5-l. These requirements apply to the primary measurement
system and assume use of a microprocessor digital recording system. If an
analog system is used for backup, the values for system accuracy may be
relaxed by 50 percent. Recommended response characteristics for
meteorological sensors are given in Table 5-2. Manufacturer's documentation
verifying an instrument's response characteristics should be reviewed to
ensure that verification tests are conducted in a laboratory setting
according to accepted scientific/technical methods. Data bases for use in
regulatory dispersion modeling applications should be 90 percent complete
(before substitution). The 90 percent requirement applies to each
meteorological variable separately and to the joint recovery of wind
direction, wind speed, and stability. Compliance with the 90 percent
requirement should be assessed on a quarterly basis.
5. SYSTEM PERFORMANCE
5.1 System Accuracies
5.2 Response Characteristics of Meteorological Sensors
5.3 Data Recovery
5.3.1 Length of Record
5.3.2 Completeness Requirement
5.4 Recommendations